JDG InstrumentsDiscuss your application ↗

HAIER BIOMEDICAL / INCUBATORS

Your culture.
The right conditions.

Compare Haier dry-heat, CO₂ and optional multigas configurations. Start with the capacity and cleaning routine your workflow needs.

Find your matches ↗
Haier representative incubators photograph
MANUFACTURER SERIES PHOTOGRAPH / CONFIGURATION VARIES

01 / DEFINE THE FIT

A few choices.
A useful shortlist.

Select what matters, leave the rest open, then find your matches.

All three fields are optional. Sterilization choices adjust to the selected capacity and type. Global models require confirmation of U.S. availability and electrical supply.

02 / EXPLORE THE MODELS

Compare your possibilities.

03 / MODEL + CONFIGURATION

Discuss this configuration ↗

Dimensions are W × D × H. Inch and pound values are calculated from millimeters and kilograms. Planning specifications do not replace installation drawings, clearances or configuration approval.

04 / SEE HOW THE FEATURES FIT

Understand the conditions.
Choose with confidence.

Animations explain concepts; they are not live readings, performance tests or validated cycles.

01 / CONTROL THE TEMPERATURE

Start with the conditions.
Then choose the chamber.

Standard direct-heat models specify ambient +5°C to 105°C. The CO₂ families specify ambient +3°C to 55°C. A chamber’s heating method and its cleaning cycle are different specifications.

Dry heat in the type filter means standard incubation without specified CO₂/O₂ control.

02 / CHOOSE THE GAS ENVIRONMENT

CO₂ comes standard.
Oxygen control is an option.

The HCP B- and E-series list IR CO₂ sensing. Haier also lists an optional oxygen module. Select multigas to find these models, then review the module and gas-supply requirements with your rep.

No oxygen module is implied as included. Range and module compatibility require confirmation.

03 / PLAN THE CLEANING ROUTINE

Match the cycle
to your workflow.

B-series CO₂ models list 180°C dry-heat sterilization; E-series CO₂ models list 90°C moist heat. Standard E-series incubators list 100°C decontamination. These are distinct routines, not interchangeable upgrades.

A built-in H₂O₂ cycle has not been verified for this range; it is not offered as a selectable model feature.

04 / UNDERSTAND HUMIDITY

Humidity generation.
Humidity control.

The CO₂ models publish high-humidity performance using a reservoir. A humidity display does not establish adjustable active RH control. For active temperature/humidity setpoints, explore Haier environmental chambers.

HHS climate chambers are a separate product family, not substitutes for a CO₂ or multigas cell-culture system.

BUILD A CONFIGURATION AROUND YOUR WORK

Start with your application.
We’ll work through the fit.

Tell us your samples, capacity, operating conditions, available power and required documentation.

Discuss your application ↗